Electric motor

An electric motor converts electrical energy into mechanical energy. Most electric motors operate through interacting magnetic fields and current-carrying conductors to generate force, although a few use electrostatic forces. The reverse process, producing electrical energy from mechanical energy, is accomplished by some type of generator such as an alternator or a dynamo. Many types of electric motors can be run as generators, and vice versa. For example a starter/generator for a gas turbine, or traction motors used on vehicles, often perform both tasks.
Electric motors

Electric motors are found in applications as diverse as industrial fans, blowers and pumps, machine tools, household appliances, power tools, and disk drives. They may be powered by direct current (e.g., a battery powered portable device or motor vehicle), or by alternating current from a central electrical distribution grid. The smallest motors may be found in electric wristwatches. Medium-size motors of highly standardized dimensions and characteristics provide convenient mechanical power for industrial uses. The very largest electric motors are used for propulsion of large ships, and for such purposes as pipeline compressors, with ratings in the millions of watts. Electric motors may be classified by the source of electric power, by their internal construction, by their application, or by the type of motion they give.

The physical principle of production of mechanical force by the interactions of an electric current and a magnetic field was known as early as 1821. Electric motors of increasing efficiency were constructed throughout the 19th century, but commercial exploitation of electric motors on a large scale required efficient electrical generators and electrical distribution networks.

History and development

The principle

The conversion of electrical energy into mechanical energy by a electromagnetic means was demonstrated by the British scientist Michael Faraday in 1821. A free-hanging wire was dipped into a pool of mercury, on which a permanent magnet was placed. When a current was passed through the wire, the wire rotated around the magnet, showing that the current gave rise to a close circular magnetic field around the wire.[4] This motor is often demonstrated in school physics classes, but brine (salt water) is sometimes used in place of the toxic mercury. This is the simplest form of a class of devices called homopolar motors. A later refinement is the Barlow's wheel. These were demonstration devices only, unsuited to practical applications due to their primitive construction.[citation needed]
Faraday's electromagnetic experiment, 1821.
In 1827, Hungarian physicist Ányos Jedlik started experimenting with devices he called "electromagnetic self-rotors". Although they were used only for instructional purposes, in 1828 Jedlik demonstrated the first device to contain the three main components of practical direct current motors: the stator, rotor and commutator. The device employed no permanent magnets, as the magnetic fields of both the stationary and revolving components were produced solely by the currents flowing through their windings
Jedlik's "electromagnetic self-rotor", 1827. (Museum of Applied Arts, Budapest. The historic motor still works perfectly today.)

The first electric motors


The first commutator-type direct current electric motor capable of turning machinery was invented by the British scientist William Sturgeon in 1832. Following Sturgeon's work, a commutator-type direct-current electric motor made with the intention of commercial use was built by Americans Emily and Thomas Davenport and patented in 1837. Their motors ran at up to 600 revolutions per minute, and powered machine tools and a printing press. Due to the high cost of the zinc electrodes required by primary battery power, the motors were commercially unsuccessful and the Davenports went bankrupt. Several inventors followed Sturgeon in the development of DC motors but all encountered the same cost issues with primary battery power. No electricity distribution had been developed at the time. Like Sturgeon's motor, there was no practical commercial market for these motors.[citation needed]

In 1855 Jedlik built a device using similar principles to those used in his electromagnetic self-rotors that was capable of useful work. He built a model electric motor-propelled vehicle that same year. There is no evidence that this experimentation was communicated to the wider scientific world at that time, or that it influenced the development of electric motors in the following decades.[citation needed]

The modern DC motor was invented by accident in 1873, when Zénobe Gramme connected the dynamo he had invented to a second similar unit, driving it as a motor. The Gramme machine was the first electric motor that was successful in the industry.[citation needed]

In 1886 Frank Julian Sprague invented the first practical DC motor, a non-sparking motor capable of constant speed under variable loads. Other Sprague electric inventions about this time greatly improved grid electric distribution (prior work done while employed by Thomas Edison), allowed power from electric motors to be returned to the electric grid, provided for electric distribution to trolleys via overhead wires and the trolley pole, and provided controls systems for electric operations. This allowed Sprague to use electric motors to invent the first electric trolley system in 1887–88 in Richmond VA, the electric elevator and control system in 1892, and the electric subway with independently powered centrally controlled cars, which was first installed in 1892 in Chicago by the South Side Elevated Railway where it became popularly known as the "L". Sprague's motor and related inventions led to an explosion of interest and use in electric motors for industry, while almost simultaneously another great inventor was developing its primary competitor, which would become much more widespread.

In 1888 Nikola Tesla invented the first practicable AC motor and with it the polyphase power transmission system. Tesla continued his work on the AC motor in the years to follow at the Westinghouse company.

The development of electric motors of acceptable efficiency was delayed for several decades by failure to recognize the extreme importance of a relatively small air gap between rotor and stator. Efficient designs have a comparatively small air gap.

The St. Louis motor, long used in classrooms to illustrate motor principles, is extremely inefficient for the same reason, as well as appearing nothing like a modern motor. Photo of a traditional form of the St. Louis motor:

Application of electric motors revolutionized industry. Industrial processes were no longer limited by power transmission using shaft, belts, compressed air or hydraulic pressure. Instead every machine could be equipped with its own electric motor, providing easy control at the point of use, and improving power transmission efficiency. Electric motors applied in agriculture eliminated human and animal muscle power from such tasks as handling grain or pumping water. Household uses of electric motors reduced heavy labor in the home and made higher standards of convenience, comfort and safety possible. Today, electric motors consume more than half of all electric energy produced.

Categorization of electric motors


The classic division of electric motors has been that of Alternating Current (AC) types vs Direct Current (DC) types. This is more a de facto convention, rather than a rigid distinction. For example, many classic DC motors run on AC power, these motors being referred to as universal motors.

Rated output power is also used to categorise motors, those of less than 746 Watts, for example, are often referred to as fractional horsepower motors (FHP) in reference to the old imperial measurement.

The ongoing trend toward electronic control further muddles the distinction, as modern drivers have moved the commutator out of the motor shell. For this new breed of motor, driver circuits are relied upon to generate sinusoidal AC drive currents, or some approximation thereof. The two best examples are: the brushless DC motor and the stepping motor, both being poly-phase AC motors requiring external electronic control, although historically, stepping motors (such as for maritime and naval gyrocompass repeaters) were driven from DC switched by contacts.

Considering all rotating (or linear) electric motors require synchronism between a moving magnetic field and a moving current sheet for average torque production, there is a clearer distinction between an asynchronous motor and synchronous types. An asynchronous motor requires slip between the moving magnetic field and a winding set to induce current in the winding set by mutual inductance; the most ubiquitous example being the common AC induction motor which must slip to generate torque. In the synchronous types, induction (or slip) is not a requisite for magnetic field or current production (e.g. permanent magnet motors, synchronous brush-less wound-rotor doubly-fed electric machine).

DC motors

A DC motor is designed to run on DC electric power. Two examples of pure DC designs are Michael Faraday's homopolar motor (which is uncommon), and the ball bearing motor, which is (so far) a novelty. By far the most common DC motor types are the brushed and brushless types, which use internal and external commutation respectively to periodicaly reverse the current in the rotor windings.

Permanent-magnet motors


A permanent-magnet motor does not have a field winding on the stator frame, instead relying on permanent magnets to provide the magnetic field against which the rotor field interacts to produce torque. Compensating windings in series with the armature may be used on large motors to improve commuation under load. Because this field is fixed, it cannot be adjusted for speed control. Permanent-magent motors are convenient in miniature motors to eliminate the power consumption of the field winding. Most larger DC motors are of the "dynamo" type, which requires current to flow in field windings to provide the stator magnetic field.

To minimize overall weight and size, miniature permanent-magnet motors may use high energy magnets made with neodymium or other strategic elements.

Brushed DC motors


DC motor design generates an oscillating current in a wound rotor, or armature, with a split ring commutator, and either a wound or permanent magnet stator. A rotor consists of one or more coils of wire wound around a core on a shaft; an electrical power source is connected to the rotor coil through the commutator and its brushes, causing current to flow in it, producing electromagnetism. The commutator causes the current in the coils to be switched as the rotor turns, keeping the magnetic poles of the rotor from ever fully aligning with the magnetic poles of the stator field, so that the rotor never stops (like a compass needle does) but rather keeps rotating indefinitely (as long as power is applied and is sufficient for the motor to overcome the shaft torque load and internal losses due to friction, etc.)

Many of the limitations of the classic commutator DC motor are due to the need for brushes to press against the commutator. This creates friction. Sparks are created by the brushes making and breaking circuits through the rotor coils as the brushes cross the insulating gaps between commutator sections. Depending on the commutator design, this may include the brushes shorting together adjacent sections—and hence coil ends—momentarily while crossing the gaps. Furthermore, the inductance of the rotor coils causes the voltage across each to rise when its circuit is opened, increasing the sparking of the brushes. This sparking limits the maximum speed of the machine, as too-rapid sparking will overheat, erode, or even melt the commutator. The current density per unit area of the brushes, in combination with their resistivity, limits the output of the motor. The making and breaking of electric contact also causes electrical noise, and the sparks additionally cause RFI. Brushes eventually wear out and require replacement, and the commutator itself is subject to wear and maintenance (on larger motors) or replacement (on small motors). The commutator assembly on a large motor is a costly element, requiring precision assembly of many parts. On small motors, the commutator is usually permanently integrated into the rotor, so replacing it usually requires replacing the whole rotor.

Large brushes are desired for a larger brush contact area to maximize motor output, but small brushes are desired for low mass to maximize the speed at which the motor can run without the brushes excessively bouncing and sparking (comparable to the problem of "valve float" in internal combustion engines). (Small brushes are also desirable for lower cost.) Stiffer brush springs can also be used to make brushes of a given mass work at a higher speed, but at the cost of greater friction losses (lower efficiency) and accelerated brush and commutator wear. Therefore, DC motor brush design entails a trade-off between output power, speed, and efficiency/wear.
A: shunt
B: series
C: compound
f = field coil

There are five types of brushed DC motor:

A. DC shunt-wound motor

B. DC series-wound motor

C. DC compound motor (two configurations):

  • Cumulative compound
  • Differentially compounded

D. Permanent magnet DC motor (not shown)

E. Separately excited (sepex) (not shown).

Brushless DC motors

Some of the problems of the brushed DC motor are eliminated in the brushless design. In this motor, the mechanical "rotating switch" or commutator/brushgear assembly is replaced by an external electronic switch synchronised to the rotor's position. Brushless motors are typically 85–90% efficient or more (higher efficiency for a brushless electric motor of up to 96.5% were reported by researchers at the Tokai University in Japan in 2009),[16] whereas DC motors with brushgear are typically 75–80% efficient.

Midway between ordinary DC motors and stepper motors lies the realm of the brushless DC motor. Built in a fashion very similar to stepper motors, these often use a permanent magnet external rotor, three phases of driving coils, one or more Hall effect sensors to sense the position of the rotor, and the associated drive electronics. The coils are activated, one phase after the other, by the drive electronics as cued by the signals from either Hall effect sensors or from the back EMF (electromotive force) of the undriven coils. In effect, they act as three-phase synchronous motors containing their own variable-frequency drive electronics. A specialized class of brushless DC motor controllers utilize EMF feedback through the main phase connections instead of Hall effect sensors to determine position and velocity. These motors are used extensively in electric radio-controlled vehicles. When configured with the magnets on the outside, these are referred to by modellers as outrunner motors.

Brushless DC motors are commonly used where precise speed control is necessary, as in computer disk drives or in video cassette recorders, the spindles within CD, CD-ROM (etc.) drives, and mechanisms within office products such as fans, laser printers and photocopiers. They have several advantages over conventional motors:

* Compared to AC fans using shaded-pole motors, they are very efficient, running much cooler than the equivalent AC motors. This cool operation leads to much-improved life of the fan's bearings.
* Without a commutator to wear out, the life of a DC brushless motor can be significantly longer compared to a DC motor using brushes and a commutator. Commutation also tends to cause a great deal of electrical and RF noise; without a commutator or brushes, a brushless motor may be used in electrically sensitive devices like audio equipment or computers.
* The same Hall effect sensors that provide the commutation can also provide a convenient tachometer signal for closed-loop control (servo-controlled) applications. In fans, the tachometer signal can be used to derive a "fan OK" signal.
* The motor can be easily synchronized to an internal or external clock, leading to precise speed control.
* Brushless motors have no chance of sparking, unlike brushed motors, making them better suited to environments with volatile chemicals and fuels. Also, sparking generates ozone which can accumulate in poorly ventilated buildings risking harm to occupants' health.
* Brushless motors are usually used in small equipment such as computers and are generally used to get rid of unwanted heat.
* They are also very quiet motors which is an advantage if being used in equipment that is affected by vibrations.

Modern DC brushless motors range in power from a fraction of a watt to many kilowatts. Larger brushless motors up to about 100 kW rating are used in electric vehicles. They also find significant use in high-performance electric model aircraft.

Coreless or ironless DC motors

Nothing in the principle of any of the motors described above requires that the iron (steel) portions of the rotor actually rotate. If the soft magnetic material of the rotor is made in the form of a cylinder, then (except for the effect of hysteresis) torque is exerted only on the windings of the electromagnets. Taking advantage of this fact is the coreless or ironless DC motor, a specialized form of a brush or brushless DC motor. Optimized for rapid acceleration, these motors have a rotor that is constructed without any iron core. The rotor can take the form of a winding-filled cylinder, or a self-supporting structure comprising only the magnet wire and the bonding material. The rotor can fit inside the stator magnets; a magnetically soft stationary cylinder inside the rotor provides a return path for the stator magnetic flux. A second arrangement has the rotor winding basket surrounding the stator magnets. In that design, the rotor fits inside a magnetically soft cylinder that can serve as the housing for the motor, and likewise provides a return path for the flux.

Because the rotor is much lighter in weight (mass) than a conventional rotor formed from copper windings on steel laminations, the rotor can accelerate much more rapidly, often achieving a mechanical time constant under 1 ms. This is especially true if the windings use aluminum rather than the heavier copper. But because there is no metal mass in the rotor to act as a heat sink, even small coreless motors must often be cooled by forced air.

Related limited-travel actuators have no core and a bonded coil placed between the poles of high-flux thin permanent magnets. These are the fast head positioners for rigid-disk ("hard disk") drives.

Printed armature or pancake DC motors

A rather unusual motor design the pancake/printed armature motor has the windings shaped as a disc running between arrays of high-flux magnets, arranged in a circle, facing the rotor and forming an axial air gap. This design is commonly known the pancake motor because of its extremely flat profile, although the technology has had many brand names since its inception, such as ServoDisc.

The printed armature (originally formed on a printed circuit board) in a printed armature motor is made from punched copper sheets that are laminated together using advanced composites to form a thin rigid disc. The printed armature has a unique construction, in the brushed motor world, in that it does not have a separate ring commutator. The brushes run directly on the armature surface making the whole design very compact.

An alternative manufacturing method is to use wound copper wire laid flat with a central conventional commutator, in a flower and petal shape. The windings are typically stabilized by being impregnated with electrical epoxy potting systems. These are filled epoxies that have moderate mixed viscosity and a long gel time. They are highlighted by low shrinkage and low exotherm, and are typically UL 1446 recognized as a potting compound for use up to 180°C (Class H) (UL File No. E 210549).

The unique advantage of ironless DC motors is that there is no cogging (vibration caused by attraction between the iron and the magnets) and parasitic eddy currents cannot form in the rotor as it is totally ironless. This can greatly improve efficiency, but variable-speed controllers must use a higher switching rate (>40 kHz) or direct current because of the decreased electromagnetic induction.

These motors were originally invented to drive the capstan(s) of magnetic tape drives, in the burgeoning computer industry. Pancake motors are still widely used in high-performance servo-controlled systems, humanoid robotic systems, industrial automation and medical devices. Due to the variety of constructions now available the technology is used in applications from high temperature military to low cost pump and basic servo applications.

Universal motors

A series-wound motor is referred to as a universal motor when it has been designed to operate on either AC or DC power. The ability to operate on AC is because the current in both the field and the armature (and hence the resultant magnetic fields) will alternate (reverse polarity) in synchronism, and hence the resulting mechanical force will occur in a constant direction.

Operating at normal power line frequencies, universal motors are often found in a range rarely larger than one kilowatt (about 1.3 horsepower). Universal motors also form the basis of the traditional railway traction motor in electric railways. In this application, the use of AC to power a motor originally designed to run on DC would lead to efficiency losses due to eddy current heating of their magnetic components, particularly the motor field pole-pieces that, for DC, would have used solid (un-laminated) iron. Although the heating effects are reduced by using laminated pole-pieces, as used for the cores of transformers and by the use of laminations of high permeability electrical steel, one solution available at start of the 20th century was for the motors to be operated from very low frequency AC supplies, with 25 and 16.7 hertz (Hz) operation being common. Because they used universal motors, locomotives using this design were also commonly capable of operating from a third rail powered by DC.

An advantage of the universal motor is that AC supplies may be used on motors which have some characteristics more common in DC motors, specifically high starting torque and very compact design if high running speeds are used. The negative aspect is the maintenance and short life problems caused by the commutator. As a result, such motors are usually used in AC devices such as food mixers and power tools which are used only intermittently, and often have high starting-torque demands. Continuous speed control of a universal motor running on AC is easily obtained by use of a thyristor circuit, while (imprecise) stepped speed control can be accomplished using multiple taps on the field coil. Household blenders that advertise many speeds frequently combine a field coil with several taps and a diode that can be inserted in series with the motor (causing the motor to run on half-wave rectified AC).

Universal motors generally run at high speeds, making them useful for appliances such as blenders, vacuum cleaners, and hair dryers where high RPM operation is desirable. They are also commonly used in portable power tools, such as drills, sanders (both disc and orbital), circular and jig saws, where the motor's characteristics work well. Many vacuum cleaner and weed trimmer motors exceed 10,000 RPM, while Dremel and other similar miniature grinders will often exceed 30,000 RPM.

Universal motors also lend themselves to electronic speed control and, as such, are an ideal choice for domestic washing machines. The motor can be used to agitate the drum (both forwards and in reverse) by switching the field winding with respect to the armature. The motor can also be run up to the high speeds required for the spin cycle.

Motor damage may occur due to overspeeding (running at an RPM in excess of design limits) if the unit is operated with no significant load. On larger motors, sudden loss of load is to be avoided, and the possibility of such an occurrence is incorporated into the motor's protection and control schemes. In some smaller applications, a fan blade attached to the shaft often acts as an artificial load to limit the motor speed to a safe value, as well as a means to circulate cooling airflow over the armature and field windings.

AC motors


In 1882, Nikola Tesla discovered the rotating magnetic field, and pioneered the use of a rotary field of force to operate machines. He exploited the principle to design a unique two-phase induction motor in 1883. In 1885, Galileo Ferraris independently researched the concept. In 1888, Ferraris published his research in a paper to the Royal Academy of Sciences in Turin.

Tesla had suggested that the commutators from a machine could be removed and the device could operate on a rotary field of force. Professor Poeschel, his teacher, stated that would be akin to building a perpetual motion machine.[17] Tesla would later attain U.S. Patent 0,416,194, Electric Motor (December 1889), which resembles the motor seen in many of Tesla's photos. This classic alternating current electro-magnetic motor was an induction motor.

Michail Osipovich Dolivo-Dobrovolsky later invented a three-phase "cage-rotor" in 1890. This type of motor is now used for the vast majority of commercial applications.

An AC motor has two parts. An stationary stator having coils supplied with AC current to produce a rotating magnetic field, and a rotor attached to the output shaft that is given a torque by the rotating field.

AC Motor with sliding rotor

Conical rotor brake motor incorporates the brake as an integral part of the conical sliding rotor. When the motor is at rest, a spring acts on the sliding rotor and forces the brake ring against the brake cap in the motor, holding the rotor stationary. When the motor is energized, its magnetic field generates both an axial and a radial component. The axial component overcomes the spring force, releasing the brake; while the radial component causes the rotor to turn. There is no additional brake control required.

Synchronous electric motor

A synchronous electric motor is an AC motor distinguished by a rotor spinning with coils passing magnets at the same rate as the alternating current and resulting magnetic field which drives it. Another way of saying this is that it has zero slip under usual operating conditions. Contrast this with an induction motor, which must slip to produce torque. A synchronous motor is like an induction motor except the rotor is excited by a DC field. Slip rings and brushes are used to conduct current to rotor. The rotor poles connect to each other and move at the same speed hence the name synchronous motor.

Induction motor

An induction motor is an asynchronous AC motor where power is transferred to the rotor by electromagnetic induction. An induction motor resembles a rotating transformer, because the stator (stationary part) is essentially the primary side of the transformer and the rotor (rotating part) is the secondary side. Polyphase induction motors are widely used in industry.

Induction motors may be further divided into squirrel-cage motors and wound-rotor motors. Squirrel-cage motors have a heavy winding made up of solid bars, usually aluminum or copper, joined by rings at the ends of the rotor. Currents induced into this winding provide the rotor magnetic field. The shape of the rotor bars determines the speed-torque characterstics. At low speeds, the current induced in the squirrel cage is nearly at line frequency and tends to flow in the outer parts of the rotor cage. As the motor accelerates, the slip frequency becomes lower, and more current flows in the interior of the winding. By shaping the bars to change the resistance of the windings portions in the interior and outer parts of the cage, effectively a variable resistance is inserted in the rotor circuit.

In a wound-rotor motor, the rotor winding is made of many turns of insulated wire and is connected to slip rings on the motor shaft. An external resistor or other control devices can be connected in the rotor circuit. Resistors allow control of the motor speed, although significant power is dissipated in the external resistance. A converter can be fed from the rotor circuit and return the slip-freqeuncy power that would otherwise be wasted back into the power system.

The wound-rotor induction motor is used primarily to start a high inertia load or a load that requires a very high starting torque across the full speed range. By correctly selecting the resistors used in the secondary resistance or slip ring starter, the motor is able to produce maximum torque at a relatively low supply current from zero speed to full speed. This type of motor also offers controllable speed.

Motor speed can be changed because the torque curve of the motor is effectively modified by the amount of resistance connected to the rotor circuit. Increasing the value of resistance will move the speed of maximum torque down. If the resistance connected to the rotor is increased beyond the point where the maximum torque occurs at zero speed, the torque will be further reduced.

When used with a load that has a torque curve that increases with speed, the motor will operate at the speed where the torque developed by the motor is equal to the load torque. Reducing the load will cause the motor to speed up, and increasing the load will cause the motor to slow down until the load and motor torque are equal. Operated in this manner, the slip losses are dissipated in the secondary resistors and can be very significant. The speed regulation and net efficiency is also very poor.

Doubly-fed electric motor

Doubly-fed electric motors have two independent multiphase windings on both the stator and the rotor, with at least one of the winding sets electronically controlled for variable speed operation. Doubly-fed electric motors are machines with an effective constant torque speed range that is twice synchronous speed for a given frequency of excitation. This is twice the constant torque speed range as singly-fed electric machines, which have only one active winding set.

A doubly-fed motor allows for a smaller electronic converter but the cost of the rotor winding and slip rings may offset the saving in the power electronics components. Difficulties with controlling speed near synchronous speed limit applications.

Singly-fed electric motor

Most AC motors are singly-fed. Singly-fed electric motors have a single multiphase winding set that is connected to a power supply. Singly-fed electric machines may be either induction or synchronous. The active winding set can be electronically controlled. Singly-fed electric machines have an effective constant torque speed range up to synchronous speed for a given excitation frequency.

Comparison of motor types

Comparison of motor types
Type Advantages Disadvantages Typical Application Typical Drive
AC polyphase induction squirrel-cage Low cost, long life,
high efficiency,
large ratings available (to 1 MW or more),
large number of standarized types
Starting inrush current can be high,
speed control requires variable frequency source
Pumps, fans, blowers, conveyors, compressors Poly-phase AC, variable frequency AC
Shaded-pole motor Low cost
Long life
Rotation slips from frequency
Low starting torque
Small ratings
low efficiency
Fans, appliances, record players Single phase AC
AC Induction
(split-phase capacitor)
High power
high starting torque
Rotation slips from frequency
Starting switch required
Appliances
Stationary Power Tools
Single phase AC
Universal motor High starting torque, compact, high speed Maintenance (brushes)
lifespan
Only small ratings economic
Drill, blender, vacuum cleaner, insulation blowers Single phase AC or DC
AC Synchronous Rotation in-sync with freq - hence no slip
More expensive Industrial motors
Clocks
Audio turntables
tape drives
Poly-phase AC
Stepper DC Precision positioning
High holding torque
High initial cost
Requires a controller
Positioning in printers and floppy drives DC
Brushless DC Long lifespan
low maintenance
High efficiency
High initial cost
Requires a controller
Hard drives
CD/DVD players
electric vehicles
DC
Brushed DC Simple speed control Maintenance (brushes)
Medium lifespan
Costly commutator and brushes
Steel mills
Paper making machines
Treadmill exercisers
automotive accessories
Direct DC or PWM
Pancake DC Compact design
Simple speed control
Medium cost
Medium lifespan
Office Equip
Fans/Pumps
Direct DC or PWM

Servo motor

A servomotor is used within a position-control or speed-control feedback control system. Servomotors are used in applications such as machine tools, pen plotters, and other control systems. Motors intended for use in a servomechanism must have well-documented characteristics for speed, torque, power. The dynamic response characteristics such as winding inductance and rotor inertia are also important; these factors limit the overall performance of the servomechanism loop. Large, powerful, but slow-responding servo loops may use conventional AC or DC motors and drive systems with position or speed feedback on the motor. As dynamic response requirements increase, more specialized motor designs such as coreless motors are used.

A servo system differs from some stepper motor applications in that the position feedback is continuous while the motor is running; a stepper system relies on the motor not to "miss steps" for short term accuracy, although a stepper system may include a "home" switch or other element to provide long-term stability of control.

Electrostatic motor

An electrostatic motor is based on the attraction and repulsion of electric charge. Usually, electrostatic motors are the dual of conventional coil-based motors. They typically require a high voltage power supply, although very small motors employ lower voltages. Conventional electric motors instead employ magnetic attraction and repulsion, and require high current at low voltages. In the 1750s, the first electrostatic motors were developed by Benjamin Franklin and Andrew Gordon. Today the electrostatic motor finds frequent use in micro-mechanical (MEMS) systems where their drive voltages are below 100 volts, and where moving, charged plates are far easier to fabricate than coils and iron cores. Also, the molecular machinery which runs living cells is often based on linear and rotary electrostatic motors.

Torque motors

A torque motor (also known as a limited torque motor) is a specialized form of induction motor which is capable of operating indefinitely while stalled, that is, with the rotor blocked from turning, without incurring damage. In this mode of operation, the motor will apply a steady torque to the load (hence the name).

A common application of a torque motor would be the supply- and take-up reel motors in a tape drive. In this application, driven from a low voltage, the characteristics of these motors allow a relatively constant light tension to be applied to the tape whether or not the capstan is feeding tape past the tape heads. Driven from a higher voltage, (and so delivering a higher torque), the torque motors can also achieve fast-forward and rewind operation without requiring any additional mechanics such as gears or clutches. In the computer gaming world, torque motors are used in force feedback steering wheels.

Another common application is the control of the throttle of an internal combustion engine in conjunction with an electronic governor. In this usage, the motor works against a return spring to move the throttle in accordance with the output of the governor. The latter monitors engine speed by counting electrical pulses from the ignition system or from a magnetic pickup [21] and, depending on the speed, makes small adjustments to the amount of current applied to the motor. If the engine starts to slow down relative to the desired speed, the current will be increased, the motor will develop more torque, pulling against the return spring and opening the throttle. Should the engine run too fast, the governor will reduce the current being applied to the motor, causing the return spring to pull back and close the throttle.

Stepper motors

Closely related in design to three-phase AC synchronous motors are stepper motors, where an internal rotor containing permanent magnets or a magnetically soft rotor with salient poles is controlled by a set of external magnets that are switched electronically. A stepper motor may also be thought of as a cross between a DC electric motor and a rotary solenoid. As each coil is energized in turn, the rotor aligns itself with the magnetic field produced by the energized field winding. Unlike a synchronous motor, in its application, the stepper motor may not rotate continuously; instead, it "steps" — starts and then quickly stops again — from one position to the next as field windings are energized and de-energized in sequence. Depending on the sequence, the rotor may turn forwards or backwards, and it may change direction, stop, speed up or slow down arbitrarily at any time.

Simple stepper motor drivers entirely energize or entirely de-energize the field windings, leading the rotor to "cog" to a limited number of positions; more sophisticated drivers can proportionally control the power to the field windings, allowing the rotors to position between the cog points and thereby rotate extremely smoothly. This mode of operation is often called microstepping. Computer controlled stepper motors are one of the most versatile forms of positioning systems, particularly when part of a digital servo-controlled system.

Stepper motors can be rotated to a specific angle in discrete steps with ease, and hence stepper motors are used for read/write head positioning in computer floppy diskette drives. They were used for the same purpose in pre-gigabyte era computer disk drives, where the precision and speed they offered was adequate for the correct positioning of the read/write head of a hard disk drive. As drive density increased, the precision and speed limitations of stepper motors made them obsolete for hard drives—the precision limitation made them unusable, and the speed limitation made them uncompetitive—thus newer hard disk drives use voice coil-based head actuator systems. (The term "voice coil" in this connection is historic; it refers to the structure in a typical (cone type) loudspeaker. This structure was used for a while to position the heads. Modern drives have a pivoted coil mount; the coil swings back and forth, something like a blade of a rotating fan. Nevertheless, like a voice coil, modern actuator coil conductors (the magnet wire) move perpendicular to the magnetic lines of force.)

Stepper motors were and still are often used in computer printers, optical scanners, and digital photocopiers to move the optical scanning element, the print head carriage (of dot matrix and inkjet printers), and the platen. Likewise, many computer plotters (which since the early 1990s have been replaced with large-format inkjet and laser printers) used rotary stepper motors for pen and platen movement; the typical alternatives here were either linear stepper motors or servomotors with complex closed-loop control systems.

So-called quartz analog wristwatches contain the smallest commonplace stepping motors; they have one coil, draw very little power, and have a permanent-magnet rotor. The same kind of motor drives battery-powered quartz clocks. Some of these watches, such as chronographs, contain more than one stepping motor.

Stepper motors were upscaled to be used in electric vehicles under the term SRM (Switched Reluctance Motor).

Linear motors

A linear motor is essentially an electric motor that has been "unrolled" so that, instead of producing a torque (rotation), it produces a straight-line force along its length by setting up a traveling electromagnetic field.

Linear motors are most commonly induction motors or stepper motors. You can find a linear motor in a maglev (Transrapid) train, where the train "flies" over the ground, and in many roller-coasters where the rapid motion of the motorless railcar is controlled by the rail. On a smaller scale, at least one letter-size (8.5" x 11") computer graphics X-Y pen plotter made by Hewlett-Packard (in the late 1970s to mid 1980's) used two linear stepper motors to move the pen along the two orthogonal axes.

Nanotube nanomotor

Researchers at University of California, Berkeley, recently developed rotational bearings based upon multiwall carbon nanotubes. By attaching a gold plate (with dimensions of the order of 100 nm) to the outer shell of a suspended multiwall carbon nanotube (like nested carbon cylinders), they are able to electrostatically rotate the outer shell relative to the inner core. These bearings are very robust; devices have been oscillated thousands of times with no indication of wear. These nanoelectromechanical systems (NEMS) are the next step in miniaturization and may find their way into commercial applications in the future.

See also:

* Molecular motors
* Electrostatic motor

Spacecraft propulsive motors


An electrically powered spacecraft propulsion system is any of a number of forms of electric motors which spacecraft can employ to gain mechanical energy in outer space. Most of these kinds of spacecraft propulsion work by electrically powering propellant to high speed, but electrodynamic tethers work by interacting with a planet's magnetosphere.

Efficiency

To calculate a motor's efficiency, the mechanical output power is divided by the electrical input power:

\eta = \frac{P_m}{P_e},

where η is energy conversion efficiency, Pe is electrical input power, and Pm is mechanical output power.

In simplest case Pe = VI, and Pm = Tω, where V is input voltage, I is input current, T is output torque, and ω is output angular velocity. It is possible to derive analytically the point of maximum efficiency. It is typically at less than 1/2 the stall torque.

Torque capability of motor types


When optimally designed for a given active current (i.e., torque current), voltage, pole-pair number, excitation frequency (i.e., synchronous speed), and core flux density, all categories of electric motors or generators will exhibit virtually the same maximum continuous shaft torque (i.e., operating torque) within a given physical size of electromagnetic core. Some applications require bursts of torque beyond the maximum operating torque, such as short bursts of torque to accelerate an electric vehicle from standstill. Always limited by magnetic core saturation or safe operating temperature rise and voltage, the capacity for torque bursts beyond the maximum operating torque differs significantly between categories of electric motors or generators.

Capacity for bursts of torque should not be confused with field weakening capability inherent in fully electromagnetic electric machines (Permanent Magnet (PM) electric machine are excluded). Field weakening, which is not available with PM electric machines, allows an electric machine to operate beyond the designed frequency of excitation.

Electric machines without a transformer circuit topology, such as Field-Wound (i.e., electromagnet) or Permanent Magnet (PM) Synchronous electric machines cannot realize bursts of torque higher than the maximum designed torque without saturating the magnetic core and rendering any increase in current as useless. Furthermore, the permanent magnet assembly of PM synchronous electric machines can be irreparably damaged, if bursts of torque exceeding the maximum operating torque rating are attempted.

Electric machines with a transformer circuit topology, such as Induction (i.e., asynchronous) electric machines, Induction Doubly-Fed electric machines, and Induction or Synchronous Wound-Rotor Doubly-Fed (WRDF) electric machines, exhibit very high bursts of torque because the active current (i.e., Magneto-Motive-Force or the product of current and winding-turns) induced on either side of the transformer oppose each other and as a result, the active current contributes nothing to the transformer coupled magnetic core flux density, which would otherwise lead to core saturation.

Electric machines that rely on Induction or Asynchronous principles short-circuit one port of the transformer circuit and as a result, the reactive impedance of the transformer circuit becomes dominant as slip increases, which limits the magnitude of active (i.e., real) current. Still, bursts of torque that are two to three times higher than the maximum design torque are realizable.

The Synchronous WRDF electric machine is the only electric machine with a truly dual ported transformer circuit topology (i.e., both ports independently excited with no short-circuited port). The dual ported transformer circuit topology is known to be unstable and requires a multiphase slip-ring-brush assembly to propagate limited power to the rotor winding set. If a precision means were available to instantaneously control torque angle and slip for synchronous operation during motoring or generating while simultaneously providing brushless power to the rotor winding set (see Brushless wound-rotor doubly-fed electric machine), the active current of the Synchronous WRDF electric machine would be independent of the reactive impedance of the transformer circuit and bursts of torque significantly higher than the maximum operating torque and far beyond the practical capability of any other type of electric machine would be realizable. Torque bursts greater than eight times operating torque have been calculated.

Uses

Electric motors are used in many, if not most, modern machines. Obvious uses would be in rotating machines such as fans, turbines, drills, the wheels on electric cars, locomotives and conveyor belts. Also, in many vibrating or oscillating machines, an electric motor spins an irregular figure with more area on one side of the axle than the other, causing it to appear to be moving up and down.

Electric motors are also popular in robotics. They are used to turn the wheels of vehicular robots, and servo motors are used to turn arms and legs in humanoid robots. In flying robots, along with helicopters, a motor causes a propeller or wide, flat blades to spin and create lift force, allowing vertical motion.

Electric motors are replacing hydraulic cylinders in airplanes and military equipment.

In industrial and manufacturing businesses, electric motors are used to turn saws and blades in cutting and slicing processes, and to spin gears and mixers (the latter very common in food manufacturing). Linear motors are often used to push products into containers horizontally.

Many kitchen appliances also use electric motors to accomplish various jobs. Food processors and grinders spin blades to chop and break up foods. Blenders use electric motors to mix liquids, and microwave ovens use motors to turn the tray food sits on. Toaster ovens also use electric motors to turn a conveyor to move food over heating elements.

DC motor

A DC motor is an electric motor that runs on direct current (DC) electricity.

Brushed

The brushed DC electric motor generates torque directly from DC power supplied to the motor by using internal commutation, stationary permanent magnets, and rotating electrical magnets. It works on the principle of Lorentz force, which states that any current carrying conductor placed within an external magnetic field experiences a torque or force known as Lorentz force. Advantages of a brushed DC motor include low initial cost, high reliability, and simple control of motor speed. Disadvantages are high maintenance and low life-span for high intensity uses. Maintenance involves regularly replacing the brushes and springs which carry the electric current, as well as cleaning or replacing the commutator. These components are necessary for transferring electrical power from outside the motor to the spinning wire windings of the rotor inside the motor.

Synchronous

Synchronous DC motors, such as the brushless DC motor and the stepper motor, require external commutation to generate torque. They lock up if driven directly by DC power. However, BLDC motors are more similar to a synchronous ac motor.

Brushless

Brushless DC motors use a rotating permanent magnet in the rotor, and stationary electrical magnets on the motor housing. A motor controller converts DC to AC. This design is simpler than that of brushed motors because it eliminates the complication of transferring power from outside the motor to the spinning rotor. Advantages of brushless motors include long life span, little or no maintenance, and high efficiency. Disadvantages include high initial cost, and more complicated motor speed controllers.

Uncommutated

Other types of DC motors require no commutation.

* homopolar motor-A homopolar motor has a magnetic field along the axis of rotation and an electric current that at some point is not parallel to the magnetic field. The name homopolar refers to the absence of polarity change.

Homopolar motors necessarily have a single-turn coil, which limits them to very low voltages. This has restricted the practical application of this type of motor.

* ball bearing motor-A ball bearing motor is an unusual electric motor that consists of two ball-bearing-type bearings, with the inner races mounted on a common conductive shaft, and the outer races connected to a high current, low voltage power supply. An alternative construction fits the outer races inside a metal tube, while the inner races are mounted on a shaft with a non-conductive section (e.g. two sleeves on an insulating rod). This method has the advantage that the tube will act as a flywheel. The direction of rotation is determined by the initial spin which is usually required to get it going.

Induction motor


An induction motor or asynchronous motor is a type of alternating current motor where power is supplied to the rotor by means of electromagnetic induction.

Animation of a squirrel-cage AC motor

An electric motor turns because of magnetic force exerted between a stationary electromagnet called the stator and a rotating electromagnet called the rotor. Different types of electric motors are distinguished by how electric current is supplied to the moving rotor. In a DC motor and a slip-ring AC motor, current is provided to the rotor directly through sliding electrical contacts called commutators and slip rings. In an induction motor, by contrast, the current is induced in the rotor without contacts by the magnetic field of the stator, through electromagnetic induction. An induction motor is sometimes called a rotating transformer because the stator (stationary part) is essentially the primary side of the transformer and the rotor (rotating part) is the secondary side. Unlike the normal transformer which changes the current by using time varying flux, induction motors use rotating magnetic fields to transform the voltage. The current in the primary side creates an electromagnetic field which interacts with the electromagnetic field of the secondary side to produce a resultant torque, thereby transforming the electrical energy into mechanical energy. Induction motors are widely used, especially polyphase induction motors, which are frequently used in industrial drives.

Induction motors are now the preferred choice for industrial motors due to their rugged construction, absence of brushes (which are required in most DC motors) and—thanks to modern power electronics—the ability to control the speed of the motor.

History


The idea of the rotating magnetic field was developed by Francois Arago (1824) and implemented first by Walter Baily. The practical induction motors were independently realized by Galileo Ferraris, in Italy, and Nikola Tesla, in the United States. Tesla had conceived the rotating magnetic field principle in 1882 and used it to invent the first brushless AC motor or induction motor in 1883. Ferraris developed the idea in 1885. In 1888, Ferraris published his research in a paper to the Royal Academy of Sciences in Turin where he detailed the theoretical foundations for understanding the way the motor operates. Separately, in the same year, Tesla gained U.S. Patent 381,968. The induction motor with a cage was invented by Mikhail Dolivo-Dobrovolsky about a year later.

Principle of operation and comparison to synchronous motors


The basic difference between an induction motor and a synchronous AC motor with a permanent magnet rotor is that in the latter the rotating magnetic field of the stator will impose an electromagnetic torque on the magnetic field of the rotor causing it to move (about a shaft) and a steady rotation of the rotor is produced. It is called synchronous because at steady state the speed of the rotor is the same as the speed of the rotating magnetic field in the stator.

By way of contrast, the induction motor does not have any permanent magnets on the rotor; instead, a current is induced in the rotor. To achieve this, stator windings are arranged around the rotor so that when energised with a polyphase supply they create a rotating magnetic field pattern which sweeps past the rotor. This changing magnetic field pattern induces current in the rotor conductors. These currents interact with the rotating magnetic field created by the stator and in effect causes a rotational motion on the rotor.
A 3-phase power supply provides a rotating magnetic field in an induction motor.

However, for these currents to be induced, the speed of the physical rotor must be less than the speed of the rotating magnetic field in the stator (the synchronous frequency ns) or else the magnetic field will not be moving relative to the rotor conductors and no currents will be induced. If by some chance this happens, the rotor typically slows slightly until a current is re-induced and then the rotor continues as before. This difference between the speed of the rotor and speed of the rotating magnetic field in the stator is called slip. It is unitless and is the ratio between the relative speed of the magnetic field as seen by the rotor (the slip speed) to the speed of the rotating stator field. Due to this, an induction motor is sometimes referred to as an asynchronous machine.

Synchronous speed

Understanding the behaviour of induction motors, it's useful to understand the differerences from a synchronous motor. That type of motor always runs at a synchronous speed- a shaft rotation frequency that is an integer fraction of the supply frequency. The synchronous speed of an induction motor is the same fraction of the supply.

It can be shown that the synchronous speed of a motor is determined by the following formula:

n_s={120\times{f}\over{p}}
where ns is the (synchronous) speed of the rotor (in rpm), f is the frequency of the AC supply (in Hz) and p is the number of magnetic poles.

For example, a 6 pole motor operating on 60 Hz power would have a speed of:

n_s={120\times{60}\over{6}}=1200\ \mathrm{rpm}

Note on the use of p - some texts refer to number of pole pairs per phase instead of number of poles per phase. For example a 6 pole motor, operating on 60 Hz power, would have 3 pole pairs. The equation of synchronous speed then becomes:

n_s={60\times{f}\over{P}}

with P being the number of pole pairs.

Slip

typical torque curve as a function of slip

The slip is a ratio relative to the synchronous speed and is calculated using:

s = \Bigl(\frac{n_s-n_r}{n_s}\Bigr)

Where

s is the slip, usually between 0 and 1
nr = rotor rotation speed (rpm)
ns = synchronous rotation speed (rpm)

Construction

The stator consists of wound 'poles' that carry the supply current to induce a magnetic field that penetrates the rotor. In a very simple motor, there would be a single projecting piece of the stator (a salient pole) for each pole, with windings around it; in fact, to optimize the distribution of the magnetic field, the windings are distributed in many slots located around the stator, but the magnetic field still has the same number of north-south alternations. The number of 'poles' can vary between motor types but the poles are always in pairs (i.e. 2, 4, 6, etc.).
Induction motors are most commonly built to run on single-phase or three-phase power, but two-phase motors also exist. In theory, two-phase and more than three phase induction motors are possible; many single-phase motors having two windings and requiring a capacitor can actually be viewed as two-phase motors, since the capacitor generates a second power phase 90 degrees from the single-phase supply and feeds it to a separate motor winding. Single-phase power is more widely available in residential buildings, but cannot produce a rotating field in the motor ( the field merely oscillates back and forth), so single-phase induction motors must incorporate some kind of starting mechanism to produce a rotating field. They would, using the simplified analogy of salient poles, have one salient pole per pole number; a four-pole motor would have four salient poles. Three-phase motors have three salient poles per pole number, so a four-pole motor would have twelve salient poles. This allows the motor to produce a rotating field, allowing the motor to start with no extra equipment and run more efficiently than a similar single-phase motor.
typical winding pattern for a 4 pole 3 phase motor (here poles are labelled W, U, V). Note the interleaving of the pole windings

There are three types of rotor:

* Squirrel-cage rotor

The most common rotor is a squirrel-cage rotor. It is made up of bars of either solid copper (most common) or aluminum that span the length of the rotor, and those solid copper or aluminium strips can be shorted or connected by a ring or some times not, i.e. the rotor can be closed or semiclosed type. The rotor bars in squirrel-cage induction motors are not straight, but have some skew to reduce noise and harmonics.

* Slip ring rotor

A slip ring rotor replaces the bars of the squirrel-cage rotor with windings that are connected to slip rings. When these slip rings are shorted, the rotor behaves similarly to a squirrel-cage rotor; they can also be connected to resistors to produce a high-resistance rotor circuit, which can be beneficial in starting

* Solid core rotor

A rotor can be made from a solid mild steel. The induced current causes the rotation.


Speed control

typical torque curves for different line frequencies

The synchronous rotational speed of the rotor (i.e. the theoretical unloaded speed with no slip) is controlled by the number of pole pairs (number of windings in the stator) and by the frequency of the supply voltage.

However, for a loaded rotor, for any given drive frequency and current and mechanical load, synchronous motors should be run in the 'operating zone' for that particular induction motor. This is the shaft rotation speed range above the peak torque. In this zone slightly increasing the slip speed increases the torque, and decreasing the slip decreases the torque. Hence in this zone the motor will tend to run at constant speed. Below the operating zone, the run speed tends to be unstable and may stall out or run at reduced shaft speed, depending on the nature of the mechanical load.

Before the development of economical semiconductor power electronics, it was difficult to vary the frequency to the motor and induction motors were mainly used in fixed speed applications. As an induction motor has no brushes and is easy to control, many older DC motors are now being replaced with THR induction motors and accompanying inverters in industrial applications.

Equivalent circuit

To understand the behavior of an induction motor when the rotational speed and supply frequency varies, it is helpful to look at the equivalent circuit. The equivalent circuit shows an electrically equivalent circuit to the motor's construction, where the two leftmost terminals would be connected to a power supply.

Equivalent circuit

On the left side of the circuit, the equivalent resistance of the stator, which consists of the copper resistance and core resistance in series, is shown as Rs. During asynchronous operation, stator also induces some reactance, which is represented by the inductor Xs. The next inductor Xr represents the effect of the rotor (commonly a squirrel-cage) passing through the stator's magnetic field. The effective resistance of the rotor (again with rotating in a magnetic field), Rr, is composed of:

  • the equivalent value of the machine's real power (which changes with the torque and the load on the machine)
  • the ohmic resistance of the stator windings and the squirrel cage of shorted rotor windings.

At idle, the induction motor equivalent circuit is essentially just Rs and Xs, which is why this machine only takes up mostly reactive power. The idle current draw is often near the rated current, due to the copper and core losses which exist even at no load. In these conditions, this is usually more than half the power loss at rated load. If the torque against the motor spindle is increased, the active current increases by Rr, and thus in the rotor.

Due to the construction of the induction motor, the two resistances both induce a magnetic field, in contrast to the three-phase synchronous machine, where the magnetic flux is induced only by the reactive current in the stator windings.

The current produces a voltage drop in the cage portion of the Rr, but only a slightly higher voltage drop in the stator windings. Consequently, the losses increase with increasing load in the rotor faster than they do in the stator. The copper resistance Rs and the "copper" resistance from the cage portion of Rr both cause I2R losses, and therefore the efficiency of the machine improves with increasing load. The efficiency of the machine reduces with temperature.

In contrast with a smaller frequency of the reactance Xs also getting smaller. In compliance with the rated current must shrink by the drive voltage delivered. Thus, the ratio of the voltage divider Rs to Xs and Rs and this increases engine power losses. In continuous operation this can only be an approximation because a nominal torque is generated because the cooling of rotor and stator is not included in the calculation. At higher than the rated speed or rated frequency induction motor can, however - in the context of isolation - are working on higher voltages and is more effective.

Frequently today, Rs / Rr are measure automatically and are thus in a position for any motor connected to automatically configure itself and thus to be protected from overload. A holding torque or speed close to zero can be achieved with a vector control. Here, too though, there can be problems with cooling since the fan is usually mounted on the rotor.

Starting of induction motors

Single Phase


In a single phase induction motor, it is necessary to provide a starting circuit to start rotation of the rotor. If this is not done, rotation may be commenced by manually giving a slight turn to the rotor. The single phase induction motor may rotate in either direction and it is only the starting circuit which determines rotational direction.

For small motors of a few watts, the start rotation is done by means of one or two single turn(s) of heavy copper wire around one corner of the pole. The current induced in the single turn is out of phase with the supply current and so causes an out-of-phase component in the magnetic field, which imparts to the field sufficient rotational character to start the motor. Starting torque is very low and efficiency is also reduced. Such shaded-pole motors are typically used in low-power applications with low or zero starting torque requirements, such as desk fans and record players.

Larger motors are provided with a second stator winding which is fed with an out-of-phase current to create a rotating magnetic field. The out-of-phase current may be derived by feeding the winding through a capacitor or it may derive from the winding having different values of inductance and resistance from the main winding.

In some designs, the second winding is disconnected once the motor is up to speed, usually either by means of a switch operated by centrifugal force acting on weights on the motor shaft or by a positive temperature coefficient thermistor which, after a few seconds of operation, heats up and increases its resistance to a high value thereby reducing the current through the second winding to an insignificant level. Other designs keep the second winding continuously energised when running, which improves torque.

Induction generator

Induction motors can also generally be run as generators if run above a critical speed (which is usually marked on the motor). Some source of electricity is needed to run the coils, but this can be provided by the motor once it is running via capacitors, or provided by external power supplies such as from a grid connection.

Synchronous motor

A synchronous electric motor is an AC motor distinguished by a rotor spinning with coils passing magnets at the same rate as the alternating current and resulting rotating magnetic field which drives it. Another way of saying this is that it has zero slip under usual operating conditions. Contrast this with an induction motor, which must slip in order to produce torque. They operate synchronously with line frequency. As with squirrel-cage induction motors, speed is determined by the number of pairs of poles and the line frequency. Synchronous motors are available in sub-fractional self-excited sizes to high-horsepower direct-current excited industrial sizes. In the fractional horsepower range, most synchronous motors are used where precise constant speed is required. In high-horsepower industrial sizes, the synchronous motor provides two important functions. First, it is a highly efficient means of converting ac energy to work. Second, it can operate at leading or unity power factor and thereby provide power-factor correction.

There are two major types of synchronous motors: non-excited and direct-current excited.

Non-excited motors are manufactured in reluctance and hysteresis designs, these motors employ a self-starting circuit and require no external excitation supply.

Reluctance designs have ratings that range from sub-fractional to about 30 hp. Sub-fractional horsepower motors have low torque, and are generally used for instrumentation applications. Moderate torque, integral horsepower motors use squirrel- cage construction with toothed rotors. When used with an adjustable frequency power supply, all motors in the drive system can be controlled at exactly the same speed. The power supply frequency determines motor operating speed.

Hysteresis motors are manufactured in sub-fractional horsepower ratings, primarily as servomotors and timing motors. More expensive than the reluctance type, hysteresis motors are used where precise constant speed is required.

DC-excited motors — Made in sizes larger than 1 hp, these motors require direct current supplied through slip rings for excitation. The direct current can be supplied from a separate source or from a dc generator directly connected to the motor shaft

Slip rings and brushes are used to conduct current to the rotor. The rotor poles connect to each other and move at the same speed - hence the name synchronous motor.

Synchronous motors fall under the category of synchronous machines which also includes the alternator (synchronous generator). These machines are commonly used in analog electric clocks, timers and other devices where correct time is required.

The speed of a synchronous motor is determined by the following formula:
v={120\times{f}\over{n}}
where v is the speed of the rotor (in rpm), f is the frequency of the AC supply (in Hz) and n is the number of magnetic poles.

Parts

A synchronous motor is composed of the following parts:

  • The stator is the outer shell of the motor, which carries the armature winding. This winding is spatially distributed for poly-phase AC current. This armature creates a rotating magnetic field inside the motor.
  • The rotor is the rotating portion of the motor. It carries field winding, which may be supplied by a DC source. On excitation, this field winding behaves as a permanent magnet.Some machines use permanent magnet in the rotor.
  • The slip rings on the rotor, to supply the DC to the field winding.
  • The stator frame contains and supports the other parts and may include bearing housings.

Large machines may include additional parts for cooling the machine, supporting the rotor, lubricating and cooling the bearings, and various protection and measurement devices.

Operation

The operation of a synchronous motor is simple to imagine. The armature winding, when excited by a poly-phase (usually 3-phase) supply, creates a rotating magnetic field inside the motor. The field winding, which acts as a permanent magnet, simply locks in with the rotating magnetic field and rotates along with it. During operation, as the field locks in with the rotating magnetic field, the motor is said to be in synchronization.

Once the motor is in operation, the speed of the motor is dependent only on the supply frequency. When the motor load is increased beyond the break down load, the motor falls out of synchronization i.e., the applied load is large enough to pull out the field winding from following the rotating magnetic field. The motor immediately stalls after it falls out of synchronization.

Starting methods

Synchronous motors are not self-starting motors. This property is due to the inertia of the rotor. When the power supply is switched on, the armature winding and field windings are excited. Instantaneously, the armature winding creates a rotating magnetic field, which revolves at the designated motor speed. The rotor, due to inertia, will not follow the revolving magnetic field. In practice, the rotor should be rotated by some other means near to the motor's synchronous speed to overcome the inertia. Once the rotor nears the synchronous speed, the field winding is excited, and the motor pulls into synchronization.

The following techniques are employed to start a synchronous motor:

  • A separate motor (called pony motor) is used to drive the rotor before it locks in into synchronization.
  • The field winding is shunted or induction motor like arrangements are made so that the synchronous motor starts as an induction motor and locks in to synchronization once it reaches speeds near its synchronous speed.
  • Reducing the input electrical frequency to get the motor starting slowly, Variable-frequency drives can be used here which have Rectifier-Inverter circuits or Cycloconverter circuits.

    Special Properties

Synchronous motors show some interesting properties, which finds applications in power factor correction. The synchronous motor can be run at lagging, unity or leading power factor. The control is with the field excitation, as described below:

* When the field excitation voltage is decreased, the motor runs in lagging power factor. The power factor by which the motor lags varies directly with the drop in excitation voltage. This condition is called under-excitation.
* When the field excitation voltage is made equal to the rated voltage, the motor runs at unity power factor.
* When the field excitation voltage is increased above the rated voltage, the motor runs at leading power factor. And the power factor by which the motor leads varies directly with the increase in field excitation voltage. This condition is called over-excitation.
* The most basic property of synchro motor is that it can be use both as a capacitor or inductor. Hence in turn it improves the power factor of system.

The leading power factor operation of synchronous motor finds application in power factor correction. Normally, all the loads connected to the power supply grid run in lagging power factor, which increases reactive power consumption in the grid, thus contributing to additional losses. In such cases, a synchronous motor with no load is connected to the grid and is run over-excited, so that the leading power factor created by synchronous motor compensates the existing lagging power factor in the grid and the overall power factor is brought close to 1 (unity power factor). If unity power factor is maintained in a grid, reactive power losses diminish to zero, increasing the efficiency of the grid. This operation of synchronous motor in over-excited mode to correct the power factor is sometimes called as Synchronous condenser.

Uses



* Synchronous motors find applications in all industrial applications where constant speed is necessary.

* Improving the power factor as Synchronous condensers.

* Electrical power plants almost always use synchronous generators because it is important to keep the frequency constant at which the generator is connected.

* Low power applications include positioning machines, where high precision is required, and robot actuators.

* Mains synchronous motors are used for electric clocks.

* Record player turntables

Advantages


Synchronous motors have the following advantages over non-synchronous motors:

* Speed is independent of the load, provided an adequate field current is applied.
* Accurate control in speed and position using open loop controls, eg. stepper motors.
* They will hold their position when a DC current is applied to both the stator and the rotor windings.
* Their power factor can be adjusted to unity by using a proper field current relative to the load. Also, a "capacitive" power factor, (current phase leads voltage phase), can be obtained by increasing this current slightly, which can help achieve a better power factor correction for the whole installation.
* Their construction allows for increased electrical efficiency when a low speed is required (as in ball mills and similar apparatus).
* They run either at the synchronous speed or they do not run at all.

Switched reluctance motor


The switched reluctance motor (SRM) is a synchronous machine which runs by reluctance
6/4 Pole SRM
torque. It has wound field coils as in a DC motor for the stator windings. The rotor however has no magnets or coils attached. The rotor of the motor becomes aligned as soon as the opposite poles of the stator become energised. In order to achieve a full rotation of the motor, the windings must be energised in the correct sequence. For example, if the poles a1 and a2 are energised then the rotor will align itself with these poles. Once this has occurred it is possible for the stator poles to be de-energised before the stator poles of b1 and b2 are energised. The rotor is now positioned at the stator poles b. This sequence continues through c before arriving back at the start. This sequence can also be reversed to achieve motion in the opposite direction. This sequence can be found to be unstable while in operation.

SRM Simple Sequence

A much more stable system can be found by using the following sequence, firstly the stator poles a1 and a2 are energised. The stator poles of b1 and b2 are then energised which pulls the rotor so that it is positioned between the stator poles of a and b. Following this the stator poles of a are de-energised and the rotor continues on to be aligned with the stator poles of b, this sequence continues through bc, c and ca before a full rotation has occurred. This sequence can also be reversed to achieve motion in the opposite direction.

SRM Simple Sequence

The advantage of this operation over the simpler version is the stable operation that it provides. It also provides a well timed sequence as the timings of the phase being both on and off are equal rather than being at a 1:2 ratio as in the simpler sequence.

Control

The control system is responsible for giving the required sequential pulses to the power circuitry in order to activate the phases as required. There are two options for producing the sequence including a microcontroller to produce the signal or a timer circuit which could also produce the desired signal.

Timer

The use of a timer circuit would be very effective in producing the necessary signal in which to control the circuit. As the required signal is very simple it could easily be implemented by digital timer, such as the 555 timer. A digital timer is more precise than any other form of timer, such as a mechanical timer. With the widespread use of digital logic within integrated circuits the cost of these timers has reduced considerably. The latest controllers in use incorporate programmable logic controllers (PLC’s) rather than electromechanical components in its implementation. Within PLC’s, the timers are normally simulated by the software incorporated in the controller; the timer is therefore controlled by the software. There are obvious advantages to this system, although the control of a soft start could be hard to implement in this way.

Microcontroller

A microcontroller is ideal for this kind of application since it enables a very precise control of the phase activation timings. It also gives the possibility of implementing a soft start function in software form, in order to reduce the amount of hardware required. This is explained in the soft start section of this article.

Soft Starter

A motor soft stator is a device used to momentarily reduce the load and torque within the motor during starting. This reduces the mechanical stresses on both the motor and shaft. The reduced current demand lowers the stress on the conductor insulation. These motor soft starters can be either mechanical or electrical:

  • Mechanical – come in the form of torque limiters utilizing clutches and various couplings,
  • Electrical – these soft starters alter the power supply to the motor to reducing the torque and current demand. This is normally performed either by reducing the supply voltage, or controlling the frequency of excitation. Since switched reluctance motors are driven by a controlled pulsed supply, frequency control is an obvious choice in this case.

Depending on the application, the soft starting regime can be controlled with particular goals in mind, such as:

  • Fixed start-up time - the start up will be controlled to achieve full speed within a fixed time
  • Current limit - the motor current can be monitored and the start up controlled to keep it below a specified limit
  • Torque limit - an intelligent starter can calculate the motor torque based on the current and voltage demand and control the start up to provide a constant starting torque.

Frequency Control

A software method of soft starting may also be achieved and be incorporated with a software implementation device for the control module. This can be done by slowly ramping the speed of the control pulses up to the final running speed. This has a major advantage of being easily controlled and changed at any point by simply altering the programming. By using this method the development time is reduced and the number of modules to implement is also reduced.

Using a C programming language, as with the control sequence above, the ramping up of the speed can be achieved. The method chosen to do so was the use of a counter, this works by instructing the program to run at different speeds as a certain number of counts have been passed. The coding for such use of a counter is shown below:

   if (Counter<=20)   //if counter is less than or equal to 20 then
Counter++; //counter plus one
else //if not
Speed = SOFT_START ; //speed = soft start

if (Counter<=30) //if counter is less than or equal to 30 then
Counter++; //counter plus one
else //if not
Speed = RUN1 ; //speed = run1

if (Counter<=40) //if counter is less than or equal to 40 then
Counter++; //counter plus one
else //if not
Speed = RUN2; //speed = run2

As can be seen above the actual speed at which it shall run is given a phrase and therefore needs to be defined at the initialisation stage. More stages are also required so that the motor shall run smoothly, any number of run speeds can be added to ensure that the ramping in speed is as smooth as possible. Alteration to the speed of ramping is also easy; there are two different methods in which this can be achieved. Firstly the defined speeds can be altered, or the actual size of the count required for the following step in speed can be changed.

The main advantage of such a soft start solution is the ease of alteration. The speed of each step can be altered easily and more steps added for smoother running of the motor.

Isolation


The electrical isolation of the control and power circuitry modules is very important and is used so that the control electronics are protected from any voltage fluctuations in the power circuitry. The major method of isolation used today are optoisolators, these isolators use short optical transmission paths to transfer a signal from one part of a circuit to another. The isolator incorporates a transmitter and a receiver, the signal therefore converts from electrical to optical before converting back to electrical thereby breaking any electrical connection between input and output.

Power Circuitry

Asymmetric Bridge Converter

The most common approach to the powering of a switched reluctance motor is to use an asymmetric bridge converter.

There are 3 phases in an asymmetric bridge converter corresponding to the phases of the switched reluctance motor. If both of the power switches on either side of the phase are turned on, then that corresponding phase shall be actuated. Once the current has risen above the set value, the switch shall turn off. The energy now stored within the motor winding shall now maintain the current in the same direction until that energy is depleted.

N+1 Switch And Diode

This basic circuitry may be altered so that fewer components are required although the circuit shall perform the same action. This efficient circuit is known as the (n+1) switch and diode configuration.

A capacitor can be added to either configuration, and is used to address noise issues by ensuring that the switching of the power switches shall not cause fluctuations in the supply voltage.